RANGE OF MANUFACTERED PRODUCTS
      BRACKISH WATER REVERSE OSMOSIS
  
  
  
  
  
  
  
 
   
 DATA SHEETS | SPECIFICATIONS | MANUALS | DRAWINGS
 
    
 
 
 Package Plants  SROA-020
to
SROA-600
 20 m³/day
to
600 m³/day
 4 x 4 x 4
to
10 x 10 x 4
 25 - 35 %
 Containerized Plants  SROB-020
to
SROB-500
 20 m³/day
to
500 m³/day
   25 - 35 %
 Modular Plants  SROC-600
to
SROC-6000
 600 m³/day
to
6,000 m³/day
 10 x 10 x 4
60 x 10 x 5
 30 - 45 %
 
 Larger systems are custom designed as follows:

    up to 20,000 m³/day containerized.
    up to 100,000 m³/day site assembled.

 The above specifications are based on the following:

    - Third year operating performance.
    - Feed water at 25 °C [Design limitations at 1 °C - 45 °C].
    - Highest recommended permeate flow and recovery .
    - Properly treated feedwater.
    - Turbidity less than 1 NTU.
    - Inlet silt density index less than 4 [Design Limitations at SDI = 5].
    - Inlet pressure of 25 - 60 psig.
    - Feed water TDS at 35,000 [Design limitations at 15,000 - 50,000 ppm].
    - Membrane feed pressure: 600 - 1200 psig.
    - Product pressure up to 15 psig.

 Electric characteristics: 230/460 V, 3 PH, 60 HZ as standard (380 V, 3    PH, 50 HZ available).

 Environment: Ventilated, indoors, ambient temperature less than 50 °C,     and shielded from direct sunlight.
  print this page
 
© EBD Water® 2006. All Rights Reserved.